# Run 03 — Material Forensics

**The fixed plant's copper, aluminum and steel balances remain OPEN.** Material
forensics establishes battery chemistry minima, physical construction scenarios
and tested accounting bounds, but does not establish qualified plant metal base
cases. No complete plant mass, finite whole-boundary metal upper bound or
material completeness percentage is asserted.

`PLANT-GB300-1GW-2026Q4-A` still implements `CFG-GB300-2026Q4`.
`SNAP-RUN03` adds research and material accounting without changing the
architecture, canonical equipment counts, operating assumptions or prior
snapshots. Run 03 ends at embodied equipment stock. Civil quantities,
semiconductor manufacturing inputs and extraction remain outside scope.

## Before the new records

The latest Run 02 branch was pulled at
`5ef3841c1b6d01aba47c7177f28d0c4c9b3b9aa2`. The governing standard, prior
findings, BOM, reconciliations, uncertainty method, handoffs, conflicts and
registers were inspected. All **193 inherited tests** and all four existing
reproducers passed before any Run 03 records were created. All 680 inherited
tracked files reproduced unchanged. The complete `SNAP-RUN02` material-balance
SHA-256 remained
`8d8e7aef912ba16f0f3be3a23464024a22f5cc20e22d1e1e66cbd69b38942729`.

[Preflight fingerprints](research/run03/baseline/preflight.json) protect all
1,717 inherited canonical entities. The new reproducer independently recalculates
that historical report and checks the fixed equipment BOM and retained evidence.
The populated plant has 107 modules. Its 6,785.714285714286 rack equivalents
are distinct from the 6,848 provisioned rack positions. Research projections
use the former where the canonical quantity specifies rack equivalents.

## What can now be attributed

| Evidence / physical scope | Defensible result | Admission and limit |
| --- | ---: | --- |
| Selected Li5 cabinets, both B2 populations | 4,924.140 t declared gross; 8,346 cabinets and 4,056,156 physical cells | Inherited exact selected assembly stock; includes modules and cells |
| LFP active-material equivalent | At least **477.494450 t** | Capacity/Faraday bound; fully lithiated equivalent, not a phase assay at deployment state of charge |
| Reversible lithium inventory | At least **21.006095 t** | Same one-electron inventory; additional electrolyte and inactive lithium remain unknown |
| Total elemental lithium in battery cabinets | **21.006095–4,467.651645 t**, base unknown | Intentionally loose ceiling: gross less mandatory non-lithium FePO4 framework; accommodates electrolyte/excess Li |
| Iron / phosphorus / oxygen within that equivalent | At least **169.032473 / 93.751841 / 193.704040 t** | Nested elemental views; iron in the cathode is not steel; do not add to compound mass |
| Whole battery copper, aluminum or steel | Separately **0–4,446.645550 t**, base unknown | Gross less minimum non-metal active-equivalent stock; maxima share a single budget |
| Selected chiller R513A | **180.830 t** | Existing design-qualified declaration retained exactly; not added again as a child inventory |

The battery cabinet specification is 60 Ah. Eighteen series modules each contain
9S3P cells, implying 20 Ah/cell. The lower-bound equation is
`n_min = N_cells × 20 Ah × 3600 C/Ah / F`; conventional atomic masses convert
moles to the equivalent and elemental inventories. This is conditional on the
selected nominal LFP capacity specification and one-electron chemistry. The
rounded 31.1 kWh figure is checked rather than silently used to alter the
canonical energy. Lithium moved into the anode at charge remains inside the
inventory; the minimum does not require a fully lithiated cathode at deployment.
See [material bounds](MATERIAL_BOUNDS.md) and the
[battery handoff](research/run03/battery/HANDOFF.md).

## Conditional constructions, kept separate

These are reproducible physical cases for matched reference objects and
unselected construction choices. Their low/base/high values describe stated
inputs or recipe assumptions. They are not confidence intervals for the selected
plant and do not close its material balance.

| Construction case | Fixed-count projection | Principal unresolved transfer |
| --- | ---: | --- |
| Four-full-conductor 800 A copper busway | **589.148 t copper conductor stock** | Selected vendor, conductor material and section unspecified |
| Four-full-conductor 800 A aluminum busway | **214.718 t aluminum conductor stock** | Alternative to the copper case, using its own catalog section |
| Thin / intermediate / thick straight pipe shells | **3,553.159 / 5,463.170 / 8,091.984 t ferrous stock** | Final wall, bore and metallurgy unselected; carbon steel and stainless steel retained separately |
| Two MGX reference busbar assemblies per rack equivalent | **303.281 / 304.226 / 305.171 t copper-grade stock** | Selected Supermicro part/count unqualified; stock designation is not an elemental copper assay |
| Two MGX reference manifold main bodies per rack equivalent | **107.646 t stainless steel** | Main-body-only geometry and selected part/count unqualified |
| Cylindrical IFR32650 cell recipe, three utilization cases | **162.814 / 172.882 / 186.476 t copper; 113.723 / 120.755 / 130.250 t aluminum** | Actual high-power cell identity unknown; module and cabinet residuals retained |
| Same cell recipe, active-equivalent inventory | **477.494 / 507.019 / 546.888 t** | Theoretical utilization / literature utilization / formation-reserve case; not a guaranteed target interval |
| Comparable copper-wound 1 MVA Galaxy PDU | **7,789.600 t gross** | Product-specific copper construction and net mass do not establish the selected generic PDU composition or ceiling |

Busway conductor mass uses `rho × area × length × conductor count`, with
3,424 rails and 12 m selected allowance per rail. Copper and aluminum are
mutually exclusive electrical material alternatives within the unchanged topology.
The conductor stock labels preserve alloy/purity scope. The battery recipes are
three distinct documented commercial families, each with three explicit
utilization inputs; no recipe mean is promoted to an observed cell.
The [scenario composition](build/run03/scenario_composition.csv) retains every
component, range, assumption, replacement relationship and provenance.

## Results by research class

**Transformers.** The 24 campus 84 MVA transformers, 428 IT 5 MVA and 214
facility 3.5 MVA stepdowns were investigated separately. The 1,712 downstream
1 MVA transformer PDUs form a further distinct class. Selected conductor,
winding geometry, cooling, impedance and compatible dry composition remain
unresolved. Bottom-up winding and core geometry reproduced three independent
published transformer designs with maximum errors of 0.209% and 1.222%,
respectively. These are engineering design comparisons, not measured hardware.
A loss/current-density winding shortcut failed against 18 published large
transformer designs: mean absolute error 21.348%, maximum 70.746%. It is
rejected, and no shortcut kg/MVA coefficient enters the base case. The
[transformer handoff](research/run03/transformers/HANDOFF.md) retains parameters,
source identity, validation errors and missing target inputs.

**UPS and generators.** The exact selected 2 MW UL UPS gross mass remains
4,710 kg, with batteries separate. A new service manual confirms internal copper
busbars but provides insufficient geometry for their mass. Its option-dependent
maximum shipping weight is not an uncertainty interval around that selected net
mass. A CE 400 V PEP retains unresolved denominator, packaging and product
mapping. Major feeder masses remain per-route-metre calculations because route
lengths are unknown. C175 engine and service-part evidence identifies nested
parts but does not prove a material composition for the selected 480 V alternator
or genset. Gross generator mass is not steel; cast iron, alternator copper,
radiator, skid, enclosure and fluids remain separate questions. See the
[electrical handoff](research/run03/electrical/HANDOFF.md).

**Batteries.** The exact cabinet topology and current capacity specification
support the minima above. Published OEM cabinet populations validate a simple
assembly mass relationship to within 0.112% on held-out populations, but its
slope includes module-associated hardware and its intercept is not steel.
A BYD cell teardown's area/areal-capacity relation predicts measured capacity
within 0.507%; collector masses lack an independent weighing check and its
technology does not establish the selected high-power cell. Literal collector
thickness reconstruction from another published teardown violates measured
gross conservation in three of five cells. That interpretation is rejected,
with the conflict retained. LFP active material, graphite, Cu/Al collectors,
ferrous casing, electrolyte, polymers and elemental views are separately tracked.

**Cooling.** Exact family specifications identify likely frame, compressor,
evaporator, coil and fan materials but not their masses. F-series direct
free-cooling fin/tube evidence is kept distinct from N-series indirect
microchannel evidence; a later generic family diagram cannot establish the
selected FH coil option. Pipe annular-section models validate against six
published physical catalog weights with maximum error 1.141%. CDU preliminary
wet and chiller legacy estimated-dry masses remain conditional, not target
ceilings. Generic warm-water CRAHs and pumps lack compatible gross bounds;
there is insufficient evidence to declare their metal contribution immaterial.
See the [cooling handoff](research/run03/cooling/HANDOFF.md).

**Compute racks.** Public MGX CAD provides disjoint copper-grade power/return
busbar solids and a stainless manifold main body. CAD metadata and BRep volume
checks agree; commercial copper-size mass checks have maximum error 0.303%.
The 1,400 A busbar rating is lower than a 140 kW rack load at its stated DC
voltage, so two assemblies are an explicit conditional reference case rather
than an observed selected rack count. Rack frames, trays, PSUs, cold plates,
PCBs, packages, HBM and networking are not multiplied into an invented
semiconductor composition. Cold plates remain nested within B1. See the
[compute handoff](research/run03/compute/HANDOFF.md).

## Copper, aluminum and steel reporting

| Material and incremental boundary | Declared/design-qualified subtotal | Expanded qualified forensic subtotal | Whole-boundary outer interval | Status |
| --- | --- | --- | --- | --- |
| Copper, each of B1 / B2 / modeled B3 | Unknown | Unknown | Lower 0; base and upper unknown | OPEN |
| Aluminum, each of B1 / B2 / modeled B3 | Unknown | Unknown | Lower 0; base and upper unknown | OPEN |
| Steel, each of B1 / B2 / modeled B3 | Unknown | Unknown | Lower 0; base and upper unknown | OPEN |

Unknown subtotals do not mean zero metal. The selected exact-gross UPS/STS/battery
subset provides finite class ceilings; other high-leverage equipment and
unrouted conductors remain unbounded. Therefore a finite whole-boundary remaining
copper exposure cannot be reported. Construction scenarios retain useful
quantities but do not become expanded qualified subtotals solely because their
arithmetic or source-object validation is precise. Each machine-readable result
reports its denominator: 1 GW normalized commissioned IT and the separately
reproduced 1.009178947368421 GW provisioned IT capacity.

## Accounting and next evidence

The [hierarchy and uncertainty method](docs/RUN_03_UNCERTAINTY.md) makes knowledge
level separate from source grade, evidence-use label and admission. Closure is
material × boundary, with explicit capable-class coverage, high-contributor
qualification, finite exposure, overlap, uncertainty and provenance criteria.
The 2% screening rule cannot pass with a null base or unbounded class.

Each equipment record retains gross mass, disjoint physical components,
nested elemental views and unresolved residual. Components or guaranteed
physical minima exceeding compatible gross fail validation. Alternative rows
replace their COMMON class record; they never add a second parent inventory.
An unresolved residual is not assigned to steel. [Priority ranking](MATERIAL_FORENSICS_PRIORITY.md)
uses material leverage as an inference, not as a coefficient.

The highest-value next evidence is selected transformer winding/core data and
conductor choices; exact PDU construction; cell SKU and high-power composition;
selected FH coil and heat-exchanger geometry; selected rack mechanical BOM;
480 V alternator parts and material masses; and busway/feeder sections and routes.
The new bounds can support future closure only after dominant unbounded classes
are resolved. No design change is required to ask those questions.

Reproduce the final research and preservation audit with
`python scripts/reproduce_run03.py`; run the full suite with
`python -m unittest discover -s tests -v`. The generated
[manifest](build/run03/manifest.json), [conservation audit](build/run03/gross_conservation.csv),
[closure criteria](build/run03/closure.csv) and
[preservation audit](build/run03/preservation.json) make these conclusions reviewable.

Final verification: **256 tests pass**, with six additional transformer-model
tests. All four inherited reproducers and the new Run 03 reproducer pass.
Seven offline research builders repeat without changing their artifacts; canonical
integration is idempotent. The final audit verifies 155 source hashes, all 217
indexed Run 03 research artifacts and all 1,717 inherited canonical entities.
Earlier generated audit files are retained at their historical versions; fresh
current validation and source checks are in `build/run03/`. Every inherited
physical output remains byte-identical.